Performance meets regulation
Commercial lighting must satisfy multiple stakeholders: employees need comfortable task illumination, customers respond to atmosphere, landlords require energy efficiency, and authorities demand compliance with DS/EN 12464-1 (indoor workplace lighting) and BR18 energy frame requirements. Trappnarco ApS navigates all four simultaneously.
We produce documentation suitable for building permit submissions, tenant fit-out approvals, and LEED / DGNB certification packages. Our commercial team includes specialists in emergency lighting coordination (DS/EN 1838) and photometric modelling using DIALux evo and Relux.
Sectors we serve
Offices & Co-working
Open-plan and cellular layouts with UGR ≤ 19, vertical illuminance on walls ≥ 50 lux, and meeting room scene presets. Hot-desk sensor integration available.
Retail & Showrooms
Merchandise accent ratios of 3:1 to 10:1, window display illumination, and flexible track systems for seasonal layout changes.
Hospitality
Restaurants, hotels, and bars with dimming curves tuned for service transitions — lunch brightness to evening intimacy without reprogramming.
Healthcare & Wellness
Clinical examination lighting (1,000 lux at task), patient room circadian support, and spa environments with IP-rated wet zone specifications.
Education
Classroom blackboard illumination, lecture hall tiered seating layouts, and library reading zones per DS/EN 12464-1 educational annex.
Public & Cultural
Gallery accent lighting (50–200 lux on artwork depending on medium), museum UV filtering, and foyer statement installations.
Commercial pricing
| Service | Scope | Price (excl. VAT) |
|---|---|---|
| Lighting survey | On-site audit up to 500 m², measurement report | 12,800 DKK |
| Small fit-out | Up to 200 m², single tenant type | 24,600 DKK |
| Medium fit-out | 200–800 m², multi-zone scheme | From 41,500 DKK |
| Large project | 800 m²+, full documentation + commissioning | From 68,200 DKK |
| Façade & signage | External illumination concept + light pollution report | 11,200 DKK |
| Emergency lighting review | Compliance check against DS/EN 1838 | 7,350 DKK |
| Hourly advisory | Architect / contractor support | 895 DKK/hour |
Deliverables
- Concept design presentation with 3D visualisations (optional add-on: 7,850 DKK)
- Technical drawings: reflected ceiling plans, power and control diagrams
- Photometric calculations with uniformity and glare reports
- Fixture specification with three budget tiers (economy, standard, premium)
- Energy consumption estimate and comparison to baseline
- Bill of quantities for tender purposes
- Site inspection during installation (two visits included in medium+ packages)
- Commissioning report and as-built documentation
Discuss your commercial project: [email protected] or +45 33 21 48 67. See also our smart lighting integration for automated commercial environments.